Motorized multi turn actuator
Product Description
Product Detail
Torque Range: 40 - 1000 Nm Direct Output
Motor specification: Class F, with thermal protector up to 135°C
Electrical interface: 2* NPT 3/4 , 1* NPT1 1/2
Ingress Protection: IP67 , Optional:IP68
Working System:On-off Type: S2 15 min, no more than 600 times per hour start.
Modulating Type: S4 50 %, up to 600 triggers per hour
Signal Feedback: Integrated fault contacts,Close the valve contact,Open the valve contact
Modulating type signal:
Input signal: 4 - 20 mA; 0 - 10 V; 2 - 10 V
Output signal: 4 - 20 mA; 0 - 10 V; 2 - 10 V
Reliable electronic system
Phase sequence self-correction
Limit and torque sensing
Absolute encoder precision detection valve position
Modular design
Mechanical interlock protection
Contact selection
1. Motor protection for AOX-M series motorized multi turn actuator.
In order to protect the motor against overheating, there are two series of thermal switch installed in the three-phase motor or single-phase motor winding inside. They are involved in the control circuit to prevent damage to the motor because of winding overheating.
2. The digital position display clearly indicates the status of valve and actuator.
3. Wide range of output torque .
Direct torque outputs range from 40 Nm to 1000Nm.When AOX-M series motorized multi turn actuator combined with a worm gearbox, the maximum torque output can be adjusted up to 50,000Nm.
Model |
Output torque |
Speed |
Maxshaft diameter |
Power |
Rated current(A)50HZ |
Flange |
Weight |
three phases |
|||||||
N·m |
RPM |
mm |
W |
380V |
ISO5210 |
Kg |
|
AOX-M-007 |
70 |
45 |
Φ28 |
400 |
2.42 |
F10 |
32 |
70 |
90 |
400 |
2.95 |
||||
AOX-M-010 |
120 |
35 |
Φ28 |
600 |
2.25 |
F10 |
38 |
120 |
70 |
600 |
3.18 |
||||
120 |
105 |
800 |
5.15 |
||||
AOX-M-020 |
300 |
34 |
Φ40 |
1100 |
4.50 |
F14 |
68 |
300 |
67 |
1100 |
6.85 |
||||
AOX-M-050 |
450 |
34 |
Φ40 |
1100 |
9.58 |
F14 |
70 |
450 |
67 |
1500 |
14.80 |
||||
AOX-M-060 |
600 |
34 |
Φ55 |
3000 |
10.89 |
F16 |
103 |
600 |
67 |
4000 |
16.50 |
||||
AOX-M-080 |
800 |
34 |
Φ55 |
3000 |
12.43 |
F16 |
103 |
800 |
67 |
4000 |
23.50 |
||||
AOX-M-100 |
1000 |
34 |
Φ55 |
4000 |
30.20 |
F16 |
103 |
Shell |
Enclosure:IP67(IP68 optional),NEMA4 and 6 |
|
Power |
Standard:380V AC/3ph Optional:110/220V AC/1ph,440V AC/3ph, 50/60Hz, ±10% |
|
Motor |
Asynchronous motor |
|
Limit switch |
1×Open/ Close, SPDT,250V AC 10A(on/off model) |
|
Auxiliary limit switch |
1×Open/ Close, SPDT,250V AC 10A(on/off model) |
|
Torque switch |
1×Open/ Close, SPDT,250V AC 10A |
|
Operating temperature |
Internal-placed thermal protection,Open 120℃ ±5℃ /Close 97℃ ±5℃ |
|
Manual operation |
Declutching mechanism,with handwheel operation |
|
Self-locking device |
Self-locking by worm and worm gear |
|
Space heater |
30W (110/220V AC) Condensation preventing (according to conditions, can be adjusted) |
|
Conduit entry |
Double seal 3×(PT3/4”、PT1”、PT1-1/2”optional) |
|
Ambient temperature |
-25℃~+70℃(-30℃、-40℃、-60℃ optional) |
|
Lubrication |
Special oil for 00 actuators |
|
Material |
Ductile iron, high-strength aluminum alloys, steel, aluminum bronze, polycarbonate |
|
Ambient humidity |
Max 90%RH |
Non-Condensing |
Anti-vibration |
X Y Z 10g,0.2~34 Hz,30 minutes |
|
External coating |
Dry powder, epoxy polyester,high anti-corrosion |
|
Overload protection |
Torque peak overload protection |
|
Display screen |
LED display (smart regulation type) |
|
Setting mode |
Non-intrusive setting (without opening the cover set type) |
|
Electrically |
Integrated control unit with a non-invasive rotary switch |
NO. |
Option cheme |
Optional |
1 |
Explosion-proof actuator (Exd Ⅱ CT4) |
AOX-M series |
2 |
Water-proof actuator (IP68,10M,250HR) |
AOX-M series |
3 |
High temperature resistance actuator (-10℃~+100℃) |
AOX-M series |
4 |
Low temperature resistance actuator (-60℃~+30℃) |
AOX-M series |
5 |
Special output drive |
AOX-M series |
Installation, maintenance and storage
1. There should be no loose clearance at all joints of the AOX-M series motorized multi turn actuator and the adjustment mechanism to ensure good adjustment effect, and the connection bolt should be evenly and symmetrically tightened during installation.
2. AOX-M series motorized multi turn actuator should be maintained frequently. For places with high vibration, always check whether the fasteners are loose, whether the connectors are in good contact and whether the locking is reliable.
3. Pay attention to the handling during transportation, and use the forklift to load and unload according to the weight of the actuator mechanism model to avoid impact and damage the quality of the product.
4. It should be stored in a dry and ventilated room. To prevent moisture intrusion from the ground, it should be placed on the shelf or separated by wooden boards.
AOX attaches great importance to product design, and the design team has strong ability of product design and innovation. AOX has complete intellectual property rights and many technical patents. We value domestically developed products, respect intellectual property, AOX team totally received 98 utility patents, and we will keeping on innovate and carry out supreme quality standard for our AOX-M series motorized multi turn actuator.
Q: Are you manufactory or trade company?
A :We are the Manufactory specialized in actuator for more than 20 years, in Ruian, Zhejiang province, China.
Q: Can we call on skype to talk about AOX-M series motorized multi turn actuator?
A: Yes, we can. What's more, there are many optional ways we can talk easily, such as e-mail,Wechat, etc.
Q:Could you special design and produce for us?
A:Yes,we can.Having profeesional engineers team,we could design and produce special AOX-M series motorized multi turn actuator as per customaer requestment.